Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 156

Advertising
background image

6-41

M-4659

Configuring the MV1000/MV2000

1

2

3

4

5

6

7

8

Index

Ethernet

TCP/IP

Set the IP address to a fixed IP address or obtain it automatically (DHCP).
Consult with your network administrator for the network parameters such as the IP
address, subnet mask, default gateway, and DNS.

When using a fixed IP address
• DHCP

Set [DHCP] to [OFF].

• IP Address

Set the IP address to assign to the RD-MV1000/RD-MV2000.

• Subnet Mask

Set the subnet mask according to the system or network to which the RD-MV1000/

RD-MV2000 belongs.

• Default Gateway

Set the IP address of the gateway.

• Host Name

Set the MV’s host name using up to 64 alphanumeric characters. You do not have to

set this parameter.

• Domain Name

Set the network domain name that the RD-MV1000/RD-MV2000 belongs to using up

to 64 characters. You do not have to set this parameter.

• Server Primary, Server Secondary

Register up to two IP addresses for the primary and secondary DNS servers.

• Domain Primary, Domain Secondary

Set up to two domain suffixes: primary and secondary.

6.6 Entering Basic Settings

Advertising