Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 214

Advertising
background image

7-40

M-4659

Time Event

Set the Time Event.

Click this tab

• On1/On2/On3/Off
Set the ON/OFF setting type of each event (16 events) from the following. Select [Off]

for events that are not to be assigned.

On1: Use On time and Off time
On2: Use On time only
On3: Use Off time only

• On-time/Off-time
Set the ON-time/OFF-time of the time event in “hh:mm:ss” format. The selectable

range is “00:00:00 to 99:59:59.” Make sure that Set On-time ≤ Off-time.

Time event display
At the bottom of the program pattern display screen, a bar showing setting of time

events is displayed according to the specified ON and OFF times.

If time events overlap with those of other segments, or in other such cases, the

specified time event may not occur. For details, see the CX1000/CX2000 User’s
Manual (IM04L31A01-01E or IM04L31A01-03E).

Repeat

Set the repeat action.
The repeat start segment, repeat end segment, and repeat frequency is displayed in the
program display screen.

Repeat action

Repeat frequency
Repeat start segment

Click this tab

Repeat end segment

• Repeat action
Select the repeat function from [Off], [On], and [Repeat].

• Repeat frequency
Set the number of repetitions when the repeat function is turned ON in the range of [1]

to [999].

7.6 Program Control Related Setup Operations

Advertising