2.3

Setting the Communication Method

Set the communications interface and parameters according to the connection between
your PC and the recorder.

Operating Method

1.

Click the CONFIG button of Launcher, or select [Launcher] - [Network

Configuration] from the menu bar.

The [Network] dialog box appears.

Communications interface selection button

2.

Select the desired network type. The color of the selected network turns blue.

3.

Set each communication parameter.

4.

When all the communication parameters are set, click [OK]. To cancel the

settings, click [Cancel].

The dialog box closes, and the settings are applied to enable communications. (If
communications are in progress, the dialog box closes and communications are re-started.)

Description of Each Communication Parameter

Ethernet

Address:

Specify the IP address or host name.

User Name: Specify the user name.
Password:

Specify the password of the user name.

Serial Interface (RS-232 or RS-422/RS-485)

Port No.:

Specify the port no. (COM1 to COM9) to be used.

Baud Rate: Specify the baud rate (2400 to 38400).
Parity:

Specify the parity check (None, Odd or Even).

Address:

Specify the address (for RS-422/RS-485 only)

Information about the Connected Recorder

Carry out the procedure below to display information about the connected recorder.

1.

Click the [CONFIG] button in the Launcher window to start the Hardware

Configurator.

2.

Choose [Comm.] - [Action] - [Hardware info] from the menu bar.