Figure 7 FC-AL and Point-to-point topologies

.

When configuring the system, use the XP LUN Configuration and Security Manager Software pane
to specify whether the hosts and array are connected by a fabric switch.

If you use a fabric switch, you must specify FC-AL or point-to-point in the XP LUN Configuration and
Security Manager Software pane (by default, FC-AL is specified). If you use a fabric switch, see the
fabric switch's documentation to learn whether you should use FC-AL or point-to-point. Some fabric
switches require that you specify point-to-point to get the system running.

If you are not using a fabric switch, you must specify FC-AL. For more information, see

Specifying

Fibre Channel topologies

.

Fibre Channel port addresses

When configuring the system, you must set addresses for Fibre Channel ports. When addressing Fibre
Channel ports, you can use the AL-PA (arbitrated-loop physical address) or loop ID as the address
(see

Table 1

).

For more information, see

Addressing Fibre Channel ports

.

Table 1 Available addresses for Fibre Channel ports

Loop ID

Port
address
(AL-PA)

Loop ID

Port
address
(AL-PA)

Loop ID

Port
address
(AL-PA)

Loop ID

Port
address
(AL-PA)

96

3A

64

72

32

B2

0

EF

97

39

65

71

33

B1

1

E8