Volume manager operations, Viewing luse configuration information, Viewing concatenated parity groups – HP StorageWorks XP Remote Web Console Software User Manual

Page 188: 188 viewing luse configuration information, 188 viewing concatenated parity groups, Viewing concatenated, Parity groups

Advertising
background image

NOTE:

If the following operations are being performed, do not perform the Volume Manager operation:

Volume migration operation by using XP Auto LUN Software
On the XP Auto LUN Software panel, confirm whether the volume migration operation is being
performed or not. For details on procedures, see

HP StorageWorks XP Auto LUN user guide: HP

XP12000 Disk Array, HP XP10000 Disk Array.

Quick restore operation by using XP Business Copy Software or Hitachi ShadowImage for z/OS
On the XP Business Copy Software or Hitachi ShadowImage for z/OS main panel, confirm
whether the quick restore operation is being performed or not. For details on procedures, see

HP

StorageWorks XP Business Copy user guide: HP XP12000 Disk Array, HP XP10000 Disk Array,
HP 200 Storage Virtualization System or Hitachi ShadowImage for z/OS user guide: HP
XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System.

Volume Manager operations

If you are going to implement changes for Volume Manager, you must have write permission for
Volume Manager, and must be in Modify mode. The array information icons are on the upper right
corner. These icons are described in detail in the HP StorageWorks XP Command View Advanced
Edition Software user guide for XP Disk Arrays
or the HP StorageWorks XP Remote Web Console
user guide for XP12000/XP10000 Disk Arrays and SVS 200
.

Viewing LUSE configuration information

You can view the current LUSE configuration on the Volume Manager pane (

Figure 84

).

The LDEV Information tree displays an outline view of CU and LDEV numbers installed on the array
in a hierarchical structure.

The LDEV Information table displays detailed information for all open-system LDEVs in the selected
CU. If you select a normal LDEV, information in this table is for the top LDEV. If you select a LUSE
volume, information in this table is for all the LDEVs in the LUSE volume.

NOTE:

If an LDEV number ends with # (for example, 00:01#), the LDEV is an external LU. For more
information about external LUs, see the

HP StorageWorks External Storage XP user guide.

NOTE:

If an LDEV number ends with V (for example, 00:01V), the LDEV is a virtual volume (V-VOL). For
more information about V-VOLs, see the

HP StorageWorks Snapshot XP user guide.

Viewing concatenated parity groups

1.

From the Volume Manager pane, select a CU number in the LDEV Information tree. The LDEV
Information table displays all LDEVs in the selected CU.

Volume Manager operations

188

Advertising
This manual is related to the following products: