Wear pad inspection, Turntable attach bolts, Battery maintenance and charging – JLG X700AJ Operator Manual User Manual

Page 114

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE

6-18

– JLG Lift –

3128790

Wear Pad Inspection

Check for distance between wear pads and boom sections.
Distance is to be no more than 1/32nd inch.

Turntable Attach Bolts

Ensure the bolts of the coupling elements (turntable) are
torqued to 183 ft-lb. (248 Nm)

Battery Maintenance and Charging

NOTE: The battery is a maintenance free battery. Do NOT

attempt to open a maintenance-free sealed battery.

External Battery Charger Use

WHEN AN EXTERNAL BATTERY CHARGER IS TO BE USED,
CHARGING HARNESS MUST BE PLUGGED INTO A GROUNDED
RECEPTACLE. IF RECEPTACLE IS NOT GROUNDED AND A MAL-
FUNCTION SHOULD OCCUR, THE MACHINE COULD CAUSE SERI-
OUS ELECTRICAL SHOCK.

1. Open battery cover.

2. Disconnect the terminal clamps from the battery poles.

3. Connect the cables of the charger to the battery poles.

and turn on the battery charger

NOTE: Re-charge voltage should never exceed 14.7 volts

and the load intensity shall be 0.2% of the value indi-
cated below and on the lid of the battery.

4. When charging is completed turn off the battery charger

before disconnecting the cables from the battery poles

5. Return the terminal clamps to the battery poles and lubri-

cate with the appropriate product

6. Close battery cover.

IT IS GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRI-
CAL/ELECTRONIC COMPONENTS. IN THE EVENT PRESSURE-
WASHING THE MACHINE IS NEEDED, ENSURE THE MACHINE IS
SHUT DOWN BEFORE PRESSURE-WASHING. SHOULD PRESSURE
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. RECOM-
MENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS ARE
SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR BRIEF
TIME PERIODS TO AVOID HEAVY SATURATION.

Advertising