SECTION 2 - PREPARATION AND INSPECTION

3128790

– JLG Lift –

2-5

MAKE SURE THE ENGINE KEY SWITCH IS ON, THE BATTERY DIS-
CONNECT SWITCH IS TURNED ON, AND THE POWER/EMERGENCY
STOP BUTTONS AT THE GROUND AND PLATFORM CONTROL BOX
IS TURNED CLOCKWISE (ON).

Function Check

MAKE SURE NO FUNCTIONS (EXCEPT TRACK FUNCTIONS) OPER-
ATE WHEN THE OUTRIGGERS ARE NOT PROPERLY SET.

After properly setting up on outriggers, perform the func-
tion check as follows:

1. From the ground control console with no load in the

platform:

a. Check that all guards protecting the function

control switches and controllers are in place.

b. Operate all functions.
c. Ensure that all machine functions are disabled

when the Emergency Stop Button is pushed in.

d. Ensure all boom functions stop when the func-

tion enable switch is released.

2. From the platform control console:

a. Ensure that the control console is firmly secured

in the proper location.

b. Check that all guards protecting the function

control switches and controllers are in place;

c. Operate all functions.
d. Ensure all boom functions stop when the foot

switch is released.

e. Ensure that all machine functions are disabled

when the Emergency Stop Button is pushed in.

f. Ensure main lift down, tower lift down, and jib lift

down, work properly when using the emer-
gency lowering controls.