Gas/diesel engine shutdown procedure, Electric engine starting procedure – JLG X700AJ Operator Manual User Manual

Page 49

Advertising
background image

SECTION 4 - MACHINE OPERATION

3128790

– JLG Lift –

4-3

Gas/Diesel Engine Shutdown Procedure

1. Remove all load and allow engine to operate at low

speed for 3-5 minutes; this allows further reduction
of internal engine temperature.

2. Turn off the gas/diesel engine by using the gas/die-

sel engine button (item 12, Figure 4-6.) on the plat-
form/remote control box.

3. The shutdown procedure takes about 1 minute, wait

for complete shut-off (display off).

4. Push POWER/EMERGENCY STOP switches at the

platform and ground in, to the off position.

5. Turn engine key to off.

Electric Engine Starting Procedure

ENSURE THE ELECTRICAL CIRCUIT BEING USED IS THE SAME
VOLTAGE AND FREQUENCY INDICATED ON THE ELECTRIC
ENGINE PLATE. USE AN AC EXTENSION CORD WITH SUFFICIENT
AMPERAGE CAPACITY TO PROPERLY POWER THE MACHINE.

CHECK THE EFFICIENCY OF THE GROUND ON THE AC CIRCUIT, IF
THE CIRCUIT IS NOT GROUNDED, INSERT A GROUND DIS-
CHARGER TO GROUND AND CONNECT IT TO THE GROUND CLAMP
ON THE MACHINE (ITEM 1 – SEE PHOTO)
.

1

2

3

Advertising