SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

3-4

– JLG Lift –

3128790

3.2 Platform/Remote Control Station

Control Position On The Ground:

This control position is for function check and maintenance
only.

Do not operate the machine from this position if anyone is in
the platform.

WHEN OPERATING THE MACHINE FROM THE GROUND POSITION
KEEP AT A DISTANCE OF AT LEAST 3 FT. (1M) FROM THE TRACKS.

Ground control position for the platform/remote control is pos-
sible by connecting the platform/remote control station to the
ground/remote control cable connector (item 1) located near
the battery in the rear of the electrical components box.
Machine electrical panel cover removed - See photo below.

NOTE: Before removing or connecting the special adapter

plug, depress the emergency stop buttons and the
key on the engine must be in the OFF position.

Unscrew the special adapter plug (item 2) from the ground/
remote cable connector (item 1) and attach to the platform/
remote flex cable in the platform when operating the platform/
remote control station at the ground position.

To enable this position it is necessary to have the key at the
ground controls (Item 2 - Figure 3-2.) turned counterclockwise
after connecting the platform/remote control box to the
ground/remote cable connector. This key switch overrides the
footswitch in the platform.

TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY
CONTROL LEVERS OR CONTROL SWITCHES CONTROLLING PLAT-
FORM MOVEMENT DO NOT RETURN TO THE OFF OR NEUTRAL
POSITION WHEN RELEASED.

NOTE: Before removing or connecting the special adapter

plug, depress the emergency stop buttons and the
key on the engine must be in the OFF position. Before
connecting the special adapter plug ensure there is
no moisture in the electrical connectors at any time.

Re-connect the special adapter plug (item 2) on the ground/
remote cable connector (item 1) as shown in photo, when
using the platform/remote control station at the platform.

1

2

Advertising