PLATFORM INTERLOCK CHECKS

To check the platform interlock, turn the ignition key to
position I and be sure the following are set:

Park brake is applied

Transmission control lever is in the (N) NEUTRAL

position

Machine outriggers are fully lowered

Machine is level

Quick Coupler locking pin is installed

It is now possible to check the platform interlock.

1. Disengage the park brake. Turn the ignition key to the

platform position. The machine should not engage in
platform mode. Reapply the park brake.

2. Shift the transmission control lever into

(F) FORWARD or (R) REVERSE. The machine
should not engage in platform mode. Shift the
transmission control back to the (N) NEUTRAL
position.

3. Raise the outriggers. The machine should not engage

in platform mode. Lower the outriggers.

4. Unlevel the machine. The machine should not engage

in platform mode. Level the machine.

5. Remove the quick coupler locking pin from the boom

head. The machine should not engage in platform
mode. Install the quick coupler locking pin.

With all the above conditions met for the machine to go into
platform mode, turn the ignition key to the platform position.

1. Disengage the park brake. The machine should

disable platform functions. Engage the park brake.

2. Shift the transmission control lever to (F) FORWARD

or (R) REVERSE. The machine should not drive in
platform mode. Shift the machine to (N) NEUTRAL.

3. Raise the outriggers. The outriggers should NOT raise

in platform mode.

4. Unlevel the machine. The machine should disable

platform functions if the machine is not level. Level the
machine.

5. Have an assistant remove the quick coupler locking

pin. The machine should disable platform functions.

9.15

PLATFORM LOAD SYSTEM CHECK

Verify proper operation of the Load Sensing System (LSS).

1. Verify platform interlock works properly. Refer to

Section 9.14, “Platform Interlock Checks.”

2. Apply park brake, shift transmission control lever into

(N) NEUTRAL, fully retract and lower the boom below
10 degrees.

3. Fully lower outriggers, lifting the front tires and ensure

that the machine is level.

4. Shut off engine and rotate key to Platform position.

5. Remove key and ensure power/emergency stop

switch is pulled up.

6. Exit cab and lock door.

7. Load a total weight of 450-540 kg (992-1,190 lb)

including the operator weight into the platform and
secure.

8. Enter platform, push and hold start switch. Release

start switch after engine starts.

9. The platform overload indicator should be illuminated.

10. Hold trigger on the function enable control joystick.

11. Actuate the boom joystick.

12. If the LSS will not allow any platform movement, the

system is working properly.

13. If platform moves the LSS is not working properly.

14. STOP and lower the platform. Shut engine off.

15. Place a Do Not Operate Tag on both the ignition key

switch and steering wheel, stating that the machine
should not be operated.

16. Contact the local JLG dealer for assistance.

WARNING

While an assistant raises the boom. DO NOT leave
the cab unattended.

Advertising