SECTION 6 - TROUBLESHOOTING

6-16

– JLG Lift –

3121187

Code 14 - Pump Motor - Disconnected

Check For These Obvious Conditions First:

• Check the Positive (+)/Negative (–) cables from the Ground Control Module to the Pump Motor studs for loose or cor-

roded connections.

Code 15 - Lift Down Valve - Disconnected

Check For These Obvious Conditions First:

• Inspect wire terminals on the lift down valve at the base of the lift cylinder for tight and secure connection.

Table 6-15. Code 14 - Pump Motor - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Check resistance across the positive (+) and negative (–) studs on

the pump motor.

SeeTable 6-2

Replace Ground

Control Module

Repair or Replace

Pump Motor or
Motor Brushes

Table 6-16. Code 15 - Lift Down Valve - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Check voltage at the P1 connector on the Ground Control Module

between pin-10 and pin-3. Is reading within spec?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 2

2.

Check resistance between the terminals on the lift down valve,

located at the base of the lift cylinder. Is reading within spec?

6 Ohms

Repair or Replace

Wiring Harness

from Ground

Control Module

Replace the

Lift Down Valve

Solenoid

3.

With the terminals still removed from the lift down valve coil, check

continuity of the wires from pins 10 and 3 on the P1 connector to the

lift down valve.

.00 Ohms

Repair or Replace

Wiring