Figure 4-2. Component Electrical Connections.

1. Ground Control Module (a)

4. Right Side Battery (b)

7. Power Cable To Left Drive Motor/Brake (a)

2. Left Side Battery (b) (c)

5. Traction Control Module (a)

8. Power Cable To Right Drive Motor/Brake (a)

3. 175 Amp Fuse

6. Left Drive Motor Harness Reverser (a)

9. Hydraulic Pump/Motor/Tank Assembly (b)

Ground Control

P1 - Horn, Alarm, Beacons, Lift Down Valve Harness (a)

P4 - Platform Joystick Harness (a)

Module Plugs:

P2 - Elevation/Speed, Charger Limit Switch Harness (a)

P5 - Joystick Protocol Harness to

P3 - Programmable Security Lock Harness (Option) (a) Traction Control Module (a)

Notes:

(a) Apply di-electric grease JLG Part Number 3020038 to wiring harness terminals, to prevent moisture from entering module.
(b) Seal NEG (–) and POS (+) posts with battery grease to prevent corrosion.
(c) An quick-disconnect is installed on the left battery (+) POSITIVE cable for easier power disconnect when servicing machine.

See Section 6 - Figure 6-3. - Troubleshooting for complete machine wiring schematic.

(+ )

(– )