SECTION 6 - TROUBLESHOOTING

3121187

– JLG Lift –

6-17

Code 16 - Lift Down Valve - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the lift down valve wiring harness or a damaged lift down valve coil.

Code 17 - Ground Control Module - In Fold Back

Check For These Obvious Conditions First:

• Has machine been operating on a continuous grade or rough terrain for a long period of time.

Table 6-17. Code 16 - Lift Down Valve - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins 10 and 3 to the lift down valve coil. Is reading within

specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the lift down valve coil. Check resis-

tance reading of the coil. Is coil within specification?

6 Ohms

Go to Step 3

Replace Coil

3.

With the terminals still removed from the lift down valve coil, check

continuity of the wires from pins 10 and 3 on the P1 connector to the

lift down valve.

.00 Ohms

Repair or Replace

Wiring

Table 6-18. Code 17 - Ground Control Module - In Fold Back

STEP

ACTION

SPEC

YES

NO

1.

Allow Ground Control Module to cool for 30 minutes. Does the

machine operate OK after cooling.

Replace Ground

Control Module

NOTE: If this is a recurring problem compare current draw of your machine with Ground Control Module specifications in

Table 6-3 - Amperage Draw for Various Components.