Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (SSV-10)

Level-2: Service Level Settings On LCD Display: YES =

HIGH =

Level-3: Operator Level Settings NO =

L OW =

LEVEL

PROGRAMMABLE ITEM

FACTORY

PRESET

SETTING RANGE

2

Back to Main

Return to Programming Menu

3

Set Language

NOTE: There are two production modules available at this

time, one for North/South American and European
Languages, and one for Asian Languages.

1

1 - English

6 - Italian

2 - German

7 - Swedish

3 - Dutch

8 - Brazilian Portuguese

4 - French

9 - Finnish

5 - Spanish

2

1 - English

3 - Japanese

2 - Chinese

2

Set Maximum Lift Up Speed

100%

0 - 100%

2

Set Maximum Lift Down Speed

100%

0 - 100%

2

Zero the On-Board Tilt Sensor

NO

YES/NO

2, 3

Set Sleep Time

10 MINS

0 - 60 MINS

2

Set Polarity Of Left Pot Hole Input 1

0

0=DISABLED/1=LOW/2=HIGH

2

Set Polarity Of Right Pot Hole Input 2

0

0=DISABLED/1=LOW/2=HIGH

2

Set Polarity Of Up Limit/elevation Input

HIGH

HIGH/LOW

2

Set Polarity Of Charger Inhibit

HIGH

HIGH/LOW

2, 3

Set Polarity Of The Keypad Code

LOW

HIGH/LOW

2

Set Polarity Of Ancillary Input 1

HIGH

HIGH/LOW

2

Set Polarity Of Ancillary Input 2

LOW

HIGH/LOW

2, 3

Enable Detection Of Horn Open Circuit

NO

YES/NO

2, 3

Enable Detection Of Beacon Open Circuit

NO

YES/NO

2

Enable Obstruction Sensor System (OSS)

NO

YES/NO

2

Enable Detection Of Ancl. #1 Open Circuit

NO

YES/NO

2

Enable Detection Of Ancl #2 Open Circuit

NO

YES/NO

3

Forward Alarm Disable

NO

YES/NO

3

OSS Diagnostic

NO

YES/NO

2

Load Sensing (LSS)

OFF

OFF/CUTOUT PLAT./CUTOUT ALL

2

Aux. 1 - Inhibit - (Active when Ancilliary 1 is set to HIGH)

4

0=Inhibit Lift
1=Inhibit Drive when Platform is elevated
2=Inhibit Drive regardless of Plat. position
3=Inhibit Lift and Drive when Plat. elevated
4=Inhibit Lift and Drive regardless of Plat.
position

2

Aux. 2 - Inhibit - (Active when Ancilliary 2 is set to HIGH)

0

0=Inhibit Lift
1=Inhibit Drive when Platform is elevated
2=Inhibit Drive regardless of Plat. position
3=Inhibit Lift and Drive when Plat. elevated
4=Inhibit Lift and Drive regardless of Plat.
position

2

Aux . 1 - Tie Down

1

0=Disabled
1=trip if low at start-up
2=trip high at start-up

2

Aux. 2 - Tie Down

0

0=Disabled
1=trip if low at start-up
2=trip high at start-up

2

Mode Select Delay

5 SEC.

1 - 60 SECONDS