Code 33 - reserved, Code 34 - auxiliary #2 - inhibit, Code 35 - auxiliary #2 - tie down – JLG SSV10 Service Manual User Manual

Page 117: Code 36 - reserved, Code 37 - reserved, Code 34 - auxiliary #2 - inhibit -25, Code 35 - auxiliary #2 - tie down -25, See table 6-32, Ge 6-25, See table 6-33

Advertising
background image

SECTION 6 - TROUBLESHOOTING

3121187

– JLG Lift –

6-25

Code 33 - RESERVED

Code 34 - Auxiliary #2 - Inhibit

Check For These Obvious Conditions First:

• Open Platform Gate.
• No Pressure on the Platform Footswitch.

Code 35 - Auxiliary #2 - Tie Down

Check For These Obvious Conditions First:

• Pressure on the Platform Footswitch during machine power up.

Code 36 - RESERVED

Code 37 - RESERVED

Table 6-32. Code 34 - Auxiliary #2 - Inhibit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins-8 and 1 to the Aux. #2 component. Is reading within

specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the Aux. #2 component, check conti-

nuity of each of the wires from pins-8 and 1 on the P1 connector to

the Aux. #2 component end.

Replace the
Component

Repair or

Replace Wiring

Table 6-33. Code 35 - Auxiliary #2 - Tie Down

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins-8 and 1 to the Aux. #2 component. Is reading within

specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the Aux. #2 component, check conti-

nuity of each of the wires from pins-8 and 1 on the P1 connector to

the Aux. #2 component end.

Replace the
Component

Repair or

Replace Wiring