SECTION 3 - BASE COMPONENTS

3121187

– JLG Lift –

3-19

Battery Charge LED Indicator on Platform

Control Console

On normal power-up and operation this series of ten
(10) LEDs visually indicates the amount of charge
remaining in the batteries.

The number of LEDs lit will change depending on the
level of charge in the batteries.

•(+) All Three (3) GREEN LEDs lit up indicate maxi-

mum battery charge.

•Four (4) YELLOW LEDs indicate a two thirds to one

third battery charge remaining.

•(–) Three (3) RED LED’s lit indicate minimum battery

charge remaining. The machine will continue to
operate at this charge level but will begin to indicate
battery low voltage warning indicators.

Battery Low Voltage Warning Indicators

The Platform Control Console and Ground Control Station
indicate battery low voltage at three (3) Warning Levels.
(See Table 3-1. following).

Table 3-1. Battery Low Voltage Warning Indicators.

WARNING

LEVEL

INDICATOR LOCATION

RESULT

ACTION REQUIRED TO

CLEAR FAULT

PLATFORM CONTROL LED

GROUND CONTROL LCD

LEVEL-1

• 3 LEDs/BARS Flashing

with an audible beep.

• Machine will Operate - No

Control Functions Locked
Out.

Charge batteries to a level of
four (4) LEDs/BARS or more
before operating.

LEVEL-2

• 2 LEDs/BARS Flashing

with an audible beep.

• Platform Lift-UP Function

is Locked Out.

Charge batteries for a mini-
mum of four (4) continuous
hours or more, or (8) LEDs/
BARS lit before operating. (a)

LEVEL-3

• 1 LED/BAR Flashing with

an audible beep.

• Drive and Platform Lift-UP

Functions Locked Out.

Charge batteries for a mini-
mum of four (4) continuous
hours or more, or (8) LEDs/
BARS lit before operating. (a)

NOTE: (a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or

until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level 2, batteries must be

charged until 8 bars are lit on the ground station LCD display to clear the fault code.