JLG SSV10 Service Manual User Manual

Page 62

Advertising
background image

SECTION 4 - CONTROL COMPONENTS

4-8

– JLG Lift –

3121187

IMPORTANT

THE MAIN CIRCUIT BOARD AND THE SMALLER LCD CIRCUIT
BOARD MOUNTED TO THE COVER ASSEMBLY, ARE CON-
NECTED BY A RIBBON CABLE. REMOVE THE COVER CARE-
FULLY ONCE THE COVER SCREWS ARE REMOVED FROM THE
BACK OF THE MODULE.

Cover Installation

1. Remove the (6) Hex Socket Screws from the Heat Sink/
Base. One screw is under the Warranty/Tamper Label.

Disconnect the Ribbon Cable

1. Ribbon Cable Connector

3. Support for Cover

2. Ribbon Cable

1

1

2

3

Release Ribbon Cable

1. Ribbon Cable Connector Tabs
(Push tabs away from connector to release
cable then slide cable out of connector)

Note: Connector works same at both ends of the ribbon cable.

Reconnecting Ribbon Cable

1. Ribbon Cable Connector Release Tabs
(Slide cable into connector then push tabs
back into connector)

Note: Connector same at both ends of the ribbon cable.

1

1

1

1