FAULT

CODE

PLATFORM

CONSOLE

LEDs

FLASHING

LCD SYMBOL SCREEN

LCD TEXT SCREEN

FAULT DESCRIPTION/
MACHINE CONDITION

FOR TROUBLESHOOTING

REFER TO

10

6

Right Brake Disconnected

DRIVE, Lift UP/DOWN

Disabled

SeeTable 6-11,

Page 6-14

11

6

Left Drive Motor

Short Circuit

DRIVE Disabled

See Table 6-12,

Page 6-15

12

6

Right Drive Motor

Short Circuit

DRIVE Disabled

See Table 6-13,

Page 6-15

13

6

Traction Module

In Fold Back

DRIVE Disabled

See Table 6-14,

Page 6-15

14

7

Pump Motor Disconnected

Lift UP Disabled

See Table 6-15,

Page 6-16

15

7

Lift Down Valve

Disconnected

Lift UP/DOWN Disabled

See Table 6-16,

Page 6-16

16

7

Down Valve or Down Valve

Circuit Short

Lift UP/DOWN Disabled

See Table 6-17,

Page 6-17

17

7

Ground Control Module

In Fold Back

(Machine Stopped)

See Table 6-18,

Page 6-17

18

Alarm or

Alarm Circuit Short

See Table 6-19,

Page 6-18

19

Alarm Disconnected

See Table 6-20,

Page 6-18

20

Beacon or

Beacon Circuit Short

See Table 6-21,

Page 6-18

21

Beacon Disconnected

See Table 6-22,

Page 6-19

22

Horn or Horn Circuit Short

See Table 6-23,

Page 6-19

Table 6-1. LCD Display - Service Fault Code Conditions