Code 21 - beacon - disconnected, Code 22 - horn - short circuit, Code 21 - beacon - short disconnected -19 – JLG SSV10 Service Manual User Manual

Page 111: Code 22 - horn - short circuit -19, See table 6-22, Ge 6-19, See table 6-23, 19 code 22 - horn - short circuit

Advertising
background image

SECTION 6 - TROUBLESHOOTING

3121187

– JLG Lift –

6-19

Code 21 - Beacon - Disconnected

Check For These Obvious Conditions First:

• Is machine equipped with flashing amber beacon light.

Code 22 - Horn - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the horn wiring harness or a damaged horn unit.

Table 6-22. Code 21 - Beacon - Short Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with a flashing amber beacon light.

Go to Step 3

Got to Step 2

2.

At the Ground Control Module enter the programming mode, check

if the Beacon light open circuit detection is enabled.

Disable It

Replace Ground

Control Module

3.

Check voltage at the P1 connector on the Ground Control Module

between pin-12 and pin-5. Is reading within specification?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 4

4.

Remove the wire terminals at the beacon, check continuity of each

of the wires from pins-12 and 5 on the P1 connector to the beacon

end.

Replace the

Beacon

Repair or

Replace Wiring

Table 6-23. Code 22 - Horn - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins-14 and 7 to the horn. Is reading within specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the horn, check continuity of each of

the wires from pins-14 and 7 on the P1 connector to the horn end.

Replace the

Horn

Repair or

Replace Wiring

Advertising