See table 6-36, Ge 6-28 – JLG SSV10 Service Manual User Manual

Page 120

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-28

– JLG Lift –

3121187

Codes (300 - 399) Traction Control Module - Fault Condition

Check For These Obvious Conditions First:

• Damage to Traction Control Module wiring harness.
• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-36. Codes (300 - 399) Traction Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval

between each power recycle. Does fault clear?

Done

Go to Step 2

2.

Is a code number displaying on the Ground Control Station?

Code - 316

Go to Step 3

Replace

Traction Control

Module

Code - 325

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with

proper Batteries

4.

Check battery voltage while charger is operating. Is voltage within

specification?

Maximum of

31 Volts DC

Replace

Traction Control

Module

Repair or Replace

Battery Charger

5.

Check for short in harness wires from Ground Control Station con-

nector P5 to Traction Module (round din plug).

Note: This harness contains 6 wires only 3 are used, (See Figure 6-

3.) Electrical Diagram.

Repair or Replace

Wiring

Advertising