JLG SSV10 Service Manual User Manual
Page 68
SECTION 4 - CONTROL COMPONENTS
4-14
– JLG Lift –
3121187
2
Acceleration (Platform Lowered)
40
1 - 100
2
Deceleration (Platform Lowered)
45
1 - 100
2
Turn Acceleration (Platform Lowered)
30
1 - 100
2
Turn Deceleration (Platform Lowered)
30
1 - 100
2
Maximum Forward Speed (Platform Lowered)
100
1 - 100
2
Minimum Forward Speed (Platform Lowered)
30
1 - 100
2
Maximum Reverse Speed (Platform Lowered)
100
1 - 100
2
Minimum Reverse Speed (Platform Lowered)
20
1 - 100
2
Maximum Turn Speed (Platform Lowered)
30
1 - 100
2
Minimum Turn Speed (Platform Lowered)
10
1 - 100
2
Minimum Forward Speed (Platform Elevated)
20
1 - 100
2
Minimum Reverse Speed (Platform Elevated)
20
1 - 100
2
Maximum Turn Speed (Platform Elevated)
10
1 - 100
2
Motor Compensation
130 mOhms
0 - 500 mOhms
Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (SSV-10)
Level-2: Service Level Settings On LCD Display: YES =
HIGH =
Level-3: Operator Level Settings NO =
L OW =
LEVEL
PROGRAMMABLE ITEM
FACTORY
PRESET
SETTING RANGE