JLG SSV10 Service Manual User Manual

Page 68

Advertising
background image

SECTION 4 - CONTROL COMPONENTS

4-14

– JLG Lift –

3121187

2

Acceleration (Platform Lowered)

40

1 - 100

2

Deceleration (Platform Lowered)

45

1 - 100

2

Turn Acceleration (Platform Lowered)

30

1 - 100

2

Turn Deceleration (Platform Lowered)

30

1 - 100

2

Maximum Forward Speed (Platform Lowered)

100

1 - 100

2

Minimum Forward Speed (Platform Lowered)

30

1 - 100

2

Maximum Reverse Speed (Platform Lowered)

100

1 - 100

2

Minimum Reverse Speed (Platform Lowered)

20

1 - 100

2

Maximum Turn Speed (Platform Lowered)

30

1 - 100

2

Minimum Turn Speed (Platform Lowered)

10

1 - 100

2

Minimum Forward Speed (Platform Elevated)

20

1 - 100

2

Minimum Reverse Speed (Platform Elevated)

20

1 - 100

2

Maximum Turn Speed (Platform Elevated)

10

1 - 100

2

Motor Compensation

130 mOhms

0 - 500 mOhms

Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (SSV-10)

Level-2: Service Level Settings On LCD Display: YES =

HIGH =

Level-3: Operator Level Settings NO =

L OW =

LEVEL

PROGRAMMABLE ITEM

FACTORY

PRESET

SETTING RANGE

Advertising