3.4 DRIVE/ELEVATION CUT-OUT SWITCH

INSTALLATION

Drive/Elevation Switch Cut-Out Switch Installation

1. Mounting Screws (a)
2. Proximity Switch (b)
3. Switch Mounting Block

4. Mounting Holes
5. Proximity Switch (b)

NOTE: (a) Apply Loctite #242 to mounting screw threads on

final assembly.
(b) The SSV-10 is designed with two (2) drive/elevation
cut-out proximity switches in the event that if one fails
the other will continue to operate. Both are plugged into
the wiring harness to the P2 connector on the Ground
Control Station. If either switch would fail the Ground
Control Module will signal a fault condition.