2 control components - installation, Ground control module, 2 control components - installation -2 – JLG SSV10 Service Manual User Manual

Page 56: Ground control module -2

Advertising
background image

SECTION 4 - CONTROL COMPONENTS

4-2

– JLG Lift –

3121187

4.2 CONTROL COMPONENTS -

INSTALLATION

IMPORTANT

BEFORE REMOVING ANY COMPONENT FROM THE ELECTRICAL
SYSTEM, DISCONNECT THE POSITIVE TERMINAL FROM THE
LEFT SIDE BATTERY.

Ground Control Module

The face of the Ground Control Module is visible from the
front of the machine and is located under the front cover. It
is mounted to a bracket on the base frame in front of the
hydraulic pump.

All electrical components on the machine operate directly
or indirectly through the Ground Control Module. The
module is currently programmed at the factory with the
machines operating profile. If replacing a Ground Control
Module the new module may require some programming
to enable any optional equipment.

For servicing and programming information for the
Ground Control Modudle, See Section 4.3, Ground Con-
trol Module - Service Proced
ure and Section 4.4, Ground
Control Module - Programming.

Ground Control Module - Installation

1. Ground Control Station Mod-

ule

2. Mounting Screws/Washers

(a)

3. P1 Connector (b)
4. P2 Connector (b)
5. P3 Connector (b)
6. P4 Connector (b)
7. P5 Connector (b)

8. From Inline Fuse (Battery +)

and To Traction Control Mod-
ule (+)

9. From Battery (–) and To

Traction Control Module (–)

10. To (+) Post on Hydraulic

Pump

11. To (–) Post on Hydraulic

Post

Note: (a) Apply Loctite #242 to screw threads on final assembly.

(b) To help seal unit from dust and moisture, apply electrical
contact grease CG60 (JLG Part# 3020038) to all electrical
connectors before assembly.

1

2

6

7

8
9

10

11

2

3

4

5