Code 23 - horn - disconnected, Code 24 - auxiliary #1 circuit - short circuit, Code 23 - horn - disconnected -20 – JLG SSV10 Service Manual User Manual

Page 112: Code 24 - auxiliary #1 circuit - short circuit -20, See table 6-24, Ge 6-20, See table 6-25, 20 code 24 - auxiliary #1 circuit - short circuit

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-20

– JLG Lift –

3121187

Code 23 - Horn - Disconnected

Check For These Obvious Conditions First:

• Is machine equipped with a horn unit.

Code 24 - Auxiliary #1 Circuit - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the Auxiliary #1 Component wiring harness or a damaged Component.

Table 6-24. Code 23 - Horn - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with a horn unit.

Go to Step 3

Got to Step 2

2.

At the Ground Control Module enter the programming mode, check

if the horn open circuit detection is enabled.

Disable It

Replace Ground

Control Module

3.

Check voltage at the P1 connector on the Ground Control Module

between pin-14 and pin-7. Is reading within specification?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 4

4.

Remove the wire terminals at the horn, check continuity of each of

the wires from pins-14 and 7 on the P1 connector to the horn end.

Replace the

Horn

Repair or

Replace Wiring

Table 6-25. Code 24 - Auxiliary #1 Circuit - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins-9 and 2 to the Aux. #1 component. Is reading within

specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the Aux. #1 component, check conti-

nuity of each of the wires from pins-9 and 2 on the P1 connector to

the Aux. #2 component end.

Replace the
Component

Repair or

Replace Wiring

Advertising