SECTION 6 - TROUBLESHOOTING

3121187

– JLG Lift –

6-21

Code 25 - Auxiliary #1 Circuit - Disconnected

Check For These Obvious Conditions First:

• Is machine equipped with a component on the Auxiliary #1 circuit.

Code 26 - Auxiliary #2 - Short Circuit

Check For These Obvious Conditions First:

• Damaged wiring in the Auxiliary #2 Component wiring harness or a damaged Component.

Table 6-26. Code 25 - Auxiliary #1 Circuit - Disconnected

STEP

ACTION

SPEC

YES

NO

1.

Is machine equipped with a

component on the Auxiliary #1 circuit

.

Go to Step 3

Got to Step 2

2.

At the Ground Control Module enter the programming mode, check

if the Auxiliary #1 open circuit detection is enabled.

Default = NO

Disable It

Replace Ground

Control Module

3.

Check voltage at the P1 connector on the Ground Control Module

between pin-9 and pin-2. Is reading within specification?

2 - 4 V DC

Replace Ground

Control Module

Go to Step 4

4.

Remove the wire terminals at the Aux. #1 component, check conti-

nuity of each of the wires from pins-9 and 2 on the P1 connector to

the Aux. #1 component.

Replace the
Component

Repair or

Replace Wiring

Table 6-27. Code 26 - Auxiliary #2 - Short Circuit

STEP

ACTION

SPEC

YES

NO

1.

At the Ground Control Module, P1 connector, check the voltage

across pins-8 and 1 to the Aux. #2 component. Is reading within

specification?

0 - 2V DC

Go to Step 2

Replace Ground

Control Module

2.

Remove the wire terminals at the Aux. #2 component, check conti-

nuity of each of the wires from pins-8 and 1 on the P1 connector to

the Aux. #2 component end.

Replace the
Component

Repair or

Replace Wiring