Code 40 - reserved, Codes 41 thru 46 - reserved, Ge 6-26 – JLG SSV10 Service Manual User Manual

Page 118: See table 6-34

Advertising
background image

SECTION 6 - TROUBLESHOOTING

6-26

– JLG Lift –

3121187

Code 38 - Battery Voltage Low - Warning Level 2 - Two (2) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
2, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code. Failure to do so,
will result in a fault code 39.

Code 39 - Battery Voltage Low - Warning Level 3 - One (1) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
1, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.

Code 40 - RESERVED

Codes 41 thru 46 - RESERVED

Codes (100 - 199) Ground Control Module - Fault Condition

Check For These Obvious Conditions First:

• That all battery and harness connectors secure and undamaged on Ground Control Module.
• Batteries have sufficient charge.
• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-34. Codes (100 - 199) Ground Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval

between each power recycle. Does fault clear?

Done

Go to Step 2

2.

Which code number is displaying?

Code 103

Go to Step 3

Replace

Ground Control

Module

Code 119

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with

proper Batteries

4.

Check battery voltage while charger is operating. Is voltage within

specification?

Maximum of

31 Volts DC

Replace

Ground Control

Module

Repair or Replace

Battery Charger

Advertising