Error states
Detected errors or maloperation of the drive are assigned to error states with definite responses.

The response can be co-ordinated with the complete drive via the error states.

Error in PROFIsafe communication
When PROFIsafe is used as safety bus:

• If errors occur in the PROFIsafe communication, the data are passivated by the PROFIsafe driver.
• After the PROFIsafe communication is reinitialised, the drive reenabled if no standstill function

has been selected.

• Events which cause an error status are sent as a diagnostic telegram via the safety bus.

Logbook
The logbook function integrated in the controller records important events in the system in

chronological order, including error states of the drive-based safety system.

Tip!
When an online connection has been established, the logbook can be displayed in the

»Engineer« via the Logbook button on the Diagnostic tab for the controller.
Detailed information on the logbook can be found in the Online Help for the controller.

Features

Error status

System error

Fault

Warning

Event

Fatal internal error

Error

Monitoring function

LED "S_Error"

On

On

On

State of the drive-based

safety system

Lockout (CPU stopped)

Error status

Normal operation

The control category

according to EN 954-1...

... has been abandoned

... has not been abandoned

Response

The motor is immediately

safely switched to torqueless

operation via

• STO

The motor is immediately safely switched to torqueless

operation via

• STO

or shutdown via

• SS1 (parameterisable)

Acknowledgement after

event has been

eliminated

• Switching off and then on

again of the 24-V supply at

the safety module

• Error acknowledgement (AIE) plug X62 (positive

signal pulse with a signal duration of 0.3 ... 10 s)

• Error acknowledgement (AIE) via safety bus (bit

"PS_AIE")

• Switching off and then on again of the 24-V supply

at the safety module

Note!

If the system error still occurs after switching the supply voltage, please contact the

Lenze service!