7.1

Parameter list | C15113

58

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15113

Parameter | Name:

C15113 | S bus: Filter control data

Data type: BITFIELD_32

Index: 9462

d

= 24F6

h

Bit-coded selection of the active bits in the safety bus control data
Display range

(min. hex value | max. hex value)

Value is bit-coded:

Information

Bit 0 STO

Safe torque off

Bit 1 SS1

Safe stop 1

Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 ES

Safe enable switch

Bit 10 Reserved
Bit 11 OMS

Safe operation mode selector

Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Bit 16 PS_AIS

Restart acknowledgement via safety bus

Bit 17 PS_AIE

Error acknowledgement via safety bus

Bit 18 Reserved
Bit 19 Reserved
Bit 20 Reserved
Bit 21 Reserved
Bit 22 Reserved
Bit 23 SSE

Emergency stop function

Bit 24 Reserved
Bit 25 Reserved
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 Reserved
Bit 30 Reserved
Bit 31 Reserved

Read access  Write access  CINH  PLC-STOP  No transfer