2 restart behaviour, Restart behaviour, 3safe configuration – Lenze E84Dxxxxx User Manual

Page 28: Danger

Advertising
background image

3

Safe configuration

3.5

Safety functions

28

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.5.1.2

Restart behaviour

The restart behaviour of the drive after a stop function has been executed can be set via the

following parameters:

• "Restart behaviour - STO, SS1" (

C15300/1

)

Restart behaviour in case of setting "Acknowledged restart"

• After a standard stop the restart must be acknowledged (AIS) via terminal or safety bus.
• After an error stop, the error must be acknowledged first (AIE), before the restart is

acknowledged with AIS.

Restart behaviour in case of setting "Automatic restart"
The higher-level control must ensure that the drive only restarts after an acknowledgement. The

stop status of the drive is reported to the higher-level control via bit STO.

Danger!

If the request for the safety function is cancelled, the drive can restart automatically.
In case of an automatic restart, you have to provide external measures which ensure

that the drive only restarts after a confirmation (EN 60204).

Acknowledgement via terminal

via safety bus

AIS

(Positive signal pulse with a signal duration

of 0.3 ... 10 s

PROFIsafe bit "PS_AIS"

Safety bus ( 33)

AIE

(Positive signal pulse with a signal duration

of 0.3 ... 10 s)

PROFIsafe bit "PS_AIE"

Safety bus ( 33)

Note!

The restart behaviour after an emergency stop corresponds to the restart behaviour

parameterised for the STO/SS1 stop function.

Advertising