7

Parameter reference

7.2

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2

Table of attributes

The table of attributes contains information which is required for communicating with the

controller via parameters.

How to read the table of attributes:

Note!

Safety-relevant parameters with write access can only be transmitted to the drive-based

safety system by safe parameter setting with the »Engineer«.

Safe parameter transfer

( 44)

Column

Meaning

Entry

Code

Parameter name

Cxxxxx

Name

Parameter short text (display text)

Text

Index

dec

Index under which the parameter is addressed

The subindex of array variables corresponds to the

Lenze subcode number.

24575 - Lenze code number

Is only required for access via a bus

system.

hex

5FFF

h

- Lenze code number

Data

DS

Data structure

E

Single variable

(only one parameter element)

A

Array variable

(several parameter elements)

DA

Number of array elements (subcodes)

Number

DT

Data type

BITFIELD_8

1 byte bit-coded

BITFIELD_16

2 byte bit coded

BITFIELD_32

4 bytes bit-coded

INTEGER_8

1 byte with sign

INTEGER_16

2 bytes with sign

INTEGER_32

4 bytes with sign

UNSIGNED_8

1 byte without sign

UNSIGNED_16

2 bytes without sign

UNSIGNED_32

4 bytes without sign

VISIBLE_STRING

ASCII string

Factor

Factor for data transmission via a bus system,

depending on the number of decimal positions

Factor

1 ≡ no decimal positions

10 ≡ 1 decimal position

100 ≡ 2 decimal positions

1000 ≡ 3 decimal positions

Access

R

Read access

Reading allowed

W

Write access

Writing permitted (by safe parameter setting with the »Engineer«)

CINH

Controller inhibit required

Writing is only possible when the controller is inhibited

Code

Name

Index

Data

Access

dec

hex

DS

DA

Data type

Factor

R

W

CINH

C15000

Status of safety functions

9575

2567

E

1

BITFIELD_32

C15003

Command status

9572

2564

E

1

UNSIGNED_16

1

C15010

Parameter set status

9565

255D

E

1

UNSIGNED_8

1

C15011

Parameter CRC

9564

255C

A

2

UNSIGNED_32

1

C15013

Parameter set creation time

9562

255A

E

1

UNSIGNED_64

1

C15014

Time of RTC parameter setting

9561

2559

E

1

VISIBLE_STRING

C15015

Time of sec. parameter setting

9560

2558

E

1

UNSIGNED_32

1

C15016

Parameter set version

9559

2557

E

1

UNSIGNED_8

1

C15017

Stored module ID

9558

2556

E

1

UNSIGNED_16

1

C15030

SD-In Sensor type

9545

2549

A

2

UNSIGNED_8

1

C15031

SD-In Sensor function

9544

2548

A

2

UNSIGNED_8

1

Advertising