6

Safe parameter transfer

44

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6

Safe parameter transfer

The functions for a safe parameter transfer are

available in the Safe transfer dialog box.
The Safe transfer dialog box is opened via the Safe

transfer button on the Safe configuration tab.

By clicking the More >> button in the Safe transfer

dialog box, the functions for password

management and general reset are displayed in

addition.
A renewed click on the button now labelled with

<< Reduce hides these functions again.

Note!

To execute the functions for a safe parameter transfer, you have to enter a device

password!
When the memory module is used for the first time together with the drive-based safety

system, the required password file for the safe parameter transfer is not yet available in

the memory module and the error message "Reading of the password file failed" is

displayed. In this case a general reset of the device is required!
With a general reset, the safe parameter set is deleted in the memory module and in the

drive-based safety system and the required password file is created in the memory

module. After this, the drive-based safety system must be re-parameterised.