5safety option 30 – Lenze E84Dxxxxx User Manual

Page 43

Advertising
background image

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

43

5

Safety option 30

5.1

Safe inputs

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of "Safe inputs" parameter group:

Sensor type/sensor function
Sensor type and function can be parameterised.

Tip!
Detailed information on sensor inputs, active and passive sensors can be found in the

manual for the drive-based safety system.

Free assignment
If "Free assignment" has been selected as sensor function, the safety function selected via this

parameter is assigned to the safe input. The following safety functions can be selected:

Safe torque off (STO)

( 29)

Safe stop 1 (SS1)

( 30)

Discrepancy time
Maximum time for which both channels of a safe input may have non-equivalent states without

the safety engineering detecting an error.

Input delay
Time between the recognition of the signal change and the effective evaluation of an input signal.

As a result, multiple and short signal changes due to contact bounce of the components are not

taken into account.

Parameter

Information

Lenze setting

Value Unit

C15030/1...2

SD-In1...2 sensor type

Input is deactivated

C15031/1...2

SD-In1...2 sensor function

Free assignment

C15032/1...2

SD-In1...2 free assignment

STO

C15033/1...2

SD-In1...2 discrepancy time

10 ms

C15034/1...2

SD-In1...2 input delay

0 ms

Note!

If an error (e.g. a discrepancy error) occurs at a safe input to which the "operation mode

selector" sensor function is assigned, then normal operation (corresponding to the OFF

state) is selected.

• The LED "S_Error" is blinking, no

STO

is tripped.

• Special operation can only be selected again if the error has been eliminated and

acknowledged.

Note!

If "No function" has been selected, no safety function is assigned to the safe input.

Function test and monitoring of the discrepancy time remain active and the status of

the input is transmitted to the control via the safety bus (if parameterised).