Functional range of the functional safety (short overview)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2

Introduction

The safety concept of the decentralised frequency inverters 8400 protec provide three safety

options depending on the device version.

Safety option 10 (SO10):

• The drive-based safety implemented in the inverter permits to connect external safety

components, e.g. passive sensors. Active sensors with self-testing signals can be directly

connected without using further components.

Safety option 20 (SO20):

• The drive is switched off safely by a higher-level safety PLC via PROFIsafe/PROFINET.

Safety option 30 (SO30):

• The safe disconnection can both be carried out by a higher-level safety PLC via PROFIsafe/

PROFINET and through the connection of active or passive sensors.

2.1

Functional range of the functional safety (short overview)

Note!

Safety options 20 and 30 can be parameterised via the »Engineer«.
The motion functions are continued to be executed by the controller. The drive-based

safety monitors the safe compliance with the limit values. When the limit values are

exceeded, the drive-based safety starts the control functions according to EN 60204-1

directly in the controller.
The safety functions are suitable for applications according to IEC 61508 to SIL 3 and

achieve the performance level (PL) e according to EN ISO 13849-1.
The requirements of the EN 954-1 standard which was valid until 30 November 2009 are

fulfilled for safety option 10 to control category 4 and for safety option 20 and 30 to

control category 3.

Detailed information on technical data and electrical installation can be found in the

mounting instructions for the 8400 protec.

Safety option

Safety function

Safety bus

PROFINET

STO

SS1

SSE

OMS

ES

Safety option 10

Safety option 20

Safety option 30