C15000 | status of safety functions, 7parameter reference – Lenze E84Dxxxxx User Manual

Page 51

Advertising
background image

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

51

7

Parameter reference

7.1

Parameter list | C15000

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15000

C15002

Parameter | Name:

C15000 | Status of safety functions

Data type: BITFIELD_32

Index: 9575

d

= 2567

h

Bit-coded status word of the safety functions
Display range

(min. hex value | max. hex value)

Value is bit-coded:

Information

Bit 0 STO active

Safe torque off (STO)

Bit 1 SS1 active

Safe stop 1 (SS1)

Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 ES active

Enable switch (ES)

Bit 10 Reserved
Bit 11 OMS

Operation mode selector (OMS)

Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Bit 16 Reserved
Bit 17 Reserved
Bit 18 Reserved
Bit 19 Reserved
Bit 20 Reserved
Bit 21 Reserved
Bit 22 Reserved
Bit 23 SSE active

Emergency stop function

Bit 24 SD-In1 active
Bit 25 SD-In2 active
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 OMS active

Safe operation mode selector

Bit 30 Reserved
Bit 31 Error active

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C15002 | Command

Data type: UNSIGNED_8

Index: 9573

d

= 2565

h

This code is for device-internal use only and must not be written to by the user!

Advertising