Safe configuration

3.6

Safety bus

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.6

Safety bus

The drive-based safety system provides parameterisable interfaces for standardised safety bus

systems. By selecting the bus system, the corresponding parameters are made available.

Short overview of "Safety bus" parameter group:

S bus: Configuration
Selection of the safety bus system used. Communication modes that are currently being supported:

• Operation without safety bus
• Operation with PROFIsafe protocol

S bus: Filter control data
Unused functions in the control data of the safety bus must be set to "Inhibit" via this parameter.

Then, these functions cannot be activated anymore via the safety bus independently of the

transmitted control data.

Parameter

Information

Lenze setting

C15100

S bus: Configuration

No safety bus

C15113

S bus: Filter control data (bit-coded):

Bit 0 STO

Passing through

Bit 1 SS1

Passing through

Bit 9 ES

Passing through

Bit 11 OMS

Passing through

Bit 16 PS_AIS

Passing through

Bit 17 PS_AIE

Passing through

Bit 23 SSE

Passing through

Unlisted bits are reserved for future extensions!