C15013 | parameter set creation time, C15014 | time of rtc parameter setting, C15015 | time of sec. parameter setting – Lenze E84Dxxxxx User Manual

Page 53: C15016 | parameter set version, C15017 | stored module id, C15016, 7parameter reference

Advertising
background image

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

53

7

Parameter reference

7.1

Parameter list | C15013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15013

C15014

C15015

C15016

C15017

Parameter | Name:

C15013 | Parameter set creation time

Data type: UNSIGNED_64

Index: 9562

d

= 255A

h

Time of parameter set creation
Display range

(min. value | unit | max. value)

0

18446744073709552000

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Parameter | Name:

C15014 | Time of RTC parameter setting

Data type: VISIBLE_STRING

Index: 9561

d

= 2559

h

Time of acceptance of the parameter set from the memory module as value of the real-time (RTC).

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C15015 | Time of sec. parameter setting

Data type: UNSIGNED_32

Index: 9560

d

= 2558

h

Time of acceptance of the parameter set from the memory module as value of the power-on time meter from the

controller
Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Parameter | Name:

C15016 | Parameter set version

Data type: UNSIGNED_8

Index: 9559

d

= 2557

h

Display of the parameter set version available in the drive-based safety system.
Selection list

(read only)

0 No current parameter set
1 Parameter set V1.0
2 Parameter set V1.1
3 Parameter set V1.2

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Parameter | Name:

C15017 | Stored module ID

Data type: UNSIGNED_16

Index: 9558

d

= 2556

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1