Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

31

3

Safe configuration

3.5

Safety functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.5.2

Operation mode selection

Short overview of "Safety functions Operation mode selection" parameter group:

3.5.2.1

Operation mode selector (OMS)

Parameter

Information

Lenze setting

Value Unit

C15200

OMS: Stop function

STO

C15201

OMS: Motion function

Free traversing

Operation Mode Selector / OMS
Description

This function serves to switch between normal operation and "special operation" of the drive.

The special operation enables the overriding of a standard stop (

STO

and

SS1

) by release

through an enable switch.

Enable switch (ES) ( 32)

Conditions

• A safe input must be parameterised and interconnected as an operation mode selector. You

can only connect and parameterise one operation mode selector. The OMS bit of the safety

bus must be deactivated. (

C15113

).

• The special operation can also be selected via the safety bus with the OMS bit unless a safety

input is set as an operation mode selector.

• The plausibility check rejects ambiguous settings until you have parameterised them

correctly.

Function

 Basic status of normal operation
 If special operation is requested, the stop function parameterised for special operation

(

STO

or

SS1

) is activated.

 A release through the enable switch enables the motion function ( free traversing)

parameterised for the special operation.

Parameter

C15200

OMS: Stop function

C15201

OMS: Motion function

• The "Free traversing" setting must be suitable for the application!

Requesting the

special operation

How to request the special operation:

• "ON state" at a safe input to which the "operation mode selector" function has been assigned

by parameter setting.

Safe inputs ( 42)

• Only if no safe input is used, the function can be activated via the safety bus by sending a data

telegram with a corresponding content to the controller.

Deactivating the

special operation

A change-over from special operation to normal operation is only possible when the drive is at

standstill (stop function

STO

or

SS1

active).

• For a restart, the restart must be acknowledged (AIS) via terminal or safety bus.

• The automatic restart is not permitted. If the "Automatic restart" is parameterised, this must

be prevented by special measures, e.g. programming in the master control.

Error behaviour

• The emergency stop function can be triggered in both operating modes.

Normal operation

Acknowledge (AIS)

for restart

Special operation

Stop function

Enable switch (ES)

Motion function

Activate OMS

Deactivate OMS

Œ



0

1

2