5 general reset of device, General reset of device, St be re-parameterised – Lenze E84Dxxxxx User Manual

Page 48: General, Reset of device, 6safe parameter transfer

Advertising
background image

6

Safe parameter transfer

6.5

General reset of device

48

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.5

General reset of device

A general reset is, among other things, required for initialising the memory module if the controller

(with the memory module) is used together with the drive-based safety system for the first time.

How to execute a general reset of the device:

1. Unless there is an online connection, establish an online connection to the device.
2. Go to the advanced Safe transfer dialog box and click As-delivered.

• The Standard password entry dialog box is displayed.

3. Enter the standard password and confirm with OK.

• The standard password is "Lenze SM301".

The general reset is executed and then a status message displays whether the action could

be carried out successfully.

4. Confirm the status message with OK.

Note!

This function serves to reset the safety system to the delivery status.

• The safe parameter set in the memory module and in the drive-based safety system is

deleted.

• The password file required for the safe parameter transfer is re-created in the memory

module. This causes the individual device password defined before to be reset to the

standard password.

• Afterwards the drive-based safety system must be re-parameterised.

Advertising