C15030 | sd-in sensor type, C15031 | sd-in sensor function, C15032 | sd-in free assignment – Lenze E84Dxxxxx User Manual

Page 54: C15031, C15030/1, C15031/1, C15032/1, 7parameter reference

Advertising
background image

7

Parameter reference

7.1

Parameter list | C15030

54

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C15030

C15031

C15032

Parameter | Name:

C15030 | SD-In Sensor type

Data type: UNSIGNED_8

Index: 9545

d

= 2549

h

Configuration of sensor types which are connected to the safe inputs.
Selection list

0 Input is deactivated
1 Passive sensor
2 Active sensor

Subcodes

Information

C15030/1

SD-In1 sensor type

C15030/2

SD-In2 sensor type

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Parameter | Name:

C15031 | SD-In Sensor function

Data type: UNSIGNED_8

Index: 9544

d

= 2548

h

Function configuration of the safe inputs.
Selection list

Information

0 Free assignment

Safety function set in C15032.

1 Emergency stop
2 Operation mode selector
3 Enable switch

Subcodes

Information

C15031/1

SD-In1 sensor function

C15031/2

SD-In2 sensor function

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Parameter | Name:

C15032 | SD-In Free assignment

Data type: UNSIGNED_8

Index: 9543

d

= 2547

h

Assignment of a safety function to a safe input.

• Only possible if the sensor function "Free assignment" is set for the safe input in C15031.

Selection list

Information

0 STO

Safe torque off (STO)

1 SS1

Safe stop 1 (SS1)

9 No function

Subcodes

Information

C15032/1

SD-In1 free assignment

C15032/2

SD-In2 free assignment

Read access  Write access  CINH  PLC STOP  No transfer Scaling factor: 1

Advertising