1 change parameter settings, Change parameter settings, 3safe configuration – Lenze E84Dxxxxx User Manual

Page 23

Advertising
background image

Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05

23

3

Safe configuration

3.1

Change parameter settings

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.1

Change parameter settings

How to change a parameter setting:

1. Select the parameter to be changed from the list.
2. Enter the new value into the Value column or select it from the defined options.

• Invalid or impermissible values are displayed in "red" in the input field.
• A selection from the list field may cause a deactivation of parameters which are now

irrelevant due to the selection (marked by a grey background colour).

3. Press <Return key> or click into another box to accept the changed value.

• By pressing the <Esc> key you can cancel the entry.

Tip!
The parameter settings of the drive-based safety system can also be displayed in the

»Engineer« parameter list (tab All parameters  category Safety option) and on the keypad.

Changes, however, are only possible via the Safe configuration tab!

Note!

Changed parameters of the drive-based safety system are not transmitted automatically

to the device, even if an online connection has been established!
The parameter set for the drive-based safety system is only safely transmitted when

clicking the Send button in the Safe transfer dialog box!

Send safe data

( 45)

Advertising