1 setting of the safety address, Setting of the safety address, 3safe configuration – Lenze E84Dxxxxx User Manual
Page 26
3
Safe configuration
3.4
General parameters
26
Lenze · 8400 protec · Drive-based safety · Software Manual · DMS 2.4 EN · 05/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.4.1
Setting of the safety address
The safety address can be set via the "Safety address" parameter (
Setting via parameter setting
• Via the parameter "safety address" (
) addresses in the range of 0 ... 65534 can be set.
Effective safety address
The effective safety address is the result of the setting via parameter setting.
• The effective safety address must match the module ID assigned in the safe parameter set.
• If "PROFIsafe" has been selected as safety bus, the effective safety address is accepted
simultaneously as the PROFIsafe target address. This address must match the corresponding
configuration of the safety PLC.
Tip!
displays the effective safety address.