Motor control file – Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual

Page 21

Advertising
background image

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012

21

Programming and Parameters

Chapter 2

Motor Control File

MON

IT

O

R

Meterin

g

023 [Speed Reference]

Summed value of ramped speed, process PI and
droop.

Default:

Min/Max:

Units:

Read Only

–/+320.0 Hz
–/+19200.0 RPM
0.1 Hz
0.1 RPM

079

024 [Commanded Torque]

Final torque reference value after limits and
filtering are applied. Percent of motor rated
torque.
Note: Added for firmware revision 4.001.

Default:

Min/Max:
Units:

Read Only

–/+800.0%
0.1%

053

025 [Speed Feedback]

This parameter displays the estimated value of
actual motor speed.

Default:

Min/Max:

Units:

Read Only

–/+320.0 Hz
–/+19200.0 RPM
0.1 Hz
0.1 RPM

Driv

e D

at

a

026 [Rated kW]

Drive power rating.

Default:

Min/Max:
Units:

Read Only

0.00/3000.00 kW
0.01 kW

027 [Rated Volts]

The drive input voltage class (208, 240, 400 etc.).

Default:

Min/Max:
Units:

Read Only

0.0/690.0 VAC
0.1 VAC

028 [Rated Amps]

The drive rated output current.

Default:

Min/Max:
Units:

Read Only

0.0/6553.5 Amps
0.1 Amps

029 [Control SW Ver]

Main Control Board software revision.

Default:

Min/Max:
Units:

Read Only

0.000/255.255
0.001

Fil

e

Gr

oup

No

.

Parameter Name & Description

Values

Rela

ted

32

32

Fil

e

Gr

ou

p

No

.

Parameter Name & Description

Values

Rela

ted

MO

TO

R

C

O

NT

ROL

M

oto

r D

ata

040 [Motor Type]

Set to match the type of motor connected.

Default:

Options:

0

0

“Induction”

“Induction”

053

041 [Motor NP Volts]

Set to the motor nameplate rated volts.

Default:

Min/Max:
Units:

Based on Drive Rating

0.0/[Rated Volts]
0.1 VAC

042 [Motor NP FLA]

Set to the motor nameplate rated full load amps.

Default:

Min/Max:
Units:

Based on Drive Rating

0.0/[Rated Amps]

×

2

0.1 Amps

047
048

043 [Motor NP Hertz]

Set to the motor nameplate rated frequency.

Default:

Min/Max:
Units:

Based on Drive Rating

5.0/320.0 Hz
0.1 Hz

044 [Motor NP RPM]

Set to the motor nameplate rated RPM.

Default:

Min/Max:
Units:

Based on Drive Rating

60.0/19200.0 RPM
1.0 RPM

045 [Motor NP Power]

Set to the motor nameplate rated power.

Default:

Min/Max:
Units:

Based on Drive Rating

0.00/5000.00
0.01 kW/HP
See

[Mtr NP Pwr Units]

046

32

32

Advertising