Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual

Page 42

Advertising
background image

42

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012

Chapter 2

Programming and Parameters

UTILIT

Y

D

iagnos

tics

234
236

[Testpoint 1 Sel]
[Testpoint 2 Sel]

Selects the function whose value is displayed in
[Testpoint x Data]. These are internal values that
are not accessible through parameters.
Note: These parameters were added for future use
in firmware revision 4.001.

Default:

Min/Max:
Units:

499

0/65535
1

235
237

[Testpoint 1 Data]
[Testpoint 2 Data]

The present value of the function
selected in [Testpoint x Sel].
Note: These parameters were added for future use
in firmware revision 4.001.

Default:

Min/Max:
Units:

Read Only

-/+32767
1

Fa

ul

ts

238 [Fault Config 1]

Enables/disables annunciation of the listed faults.

Setting bit 14 “Fan Cooling” to 1 configures the drive for a “Non-Resettable” fault (F32 “Fan
Cooling”). In this case, the drive must be powered-down and the cause of the fault must be
corrected before the fault can be cleared. Setting bit 14 to “0” will configure the drive for a “Non-
Configurable” alarm. In this case the drive will continue to run.

Notes: Bit 9 “Load Loss” should not be changed from “0”. Bit 10 was added for firmware revision
2.001. Bits 2 “Motor Stall” and 11 “Shear PNO Ac” were added for firmware revision 3.001. Bit 14
“Fan Cooling” was added for firmware revision 6.001.
1 = Enabled
0 = Disabled

240 [Fault Clear]

Resets a fault and clears the fault queue.

Default:

Options:

0

0
1
2

“Ready”

“Ready”
“Clear Faults”
“Clr Flt Que”

241 [Fault Clear Mode]

Enables/disables a fault reset (clear faults)
attempt from any source. This does not apply to
fault codes which are cleared indirectly via other
actions.

Default:

Options:

1

0
1

“Enabled”

“Disabled”
“Enabled”

242 [Power Up Marker]

Elapsed hours since initial drive power up. This
value will rollover to 0 after the drive has been
powered on for more than the max value shown.
For relevance to most recent power up see [Fault x
Time].

Default:

Min/Max:
Units:

Read Only

0.0000/429496.7295 Hr
0.1 Hr

244
246
248
250
252
254
256
258

Fil

e

Gr

oup

No

.

Parameter Name & Description

Values

Rela

ted

Name

Re

se

rv

ed

Fa

n C

ooling

Re

se

rv

ed

Re

se

rv

ed

Shear PNO A

c

Ga

te

Dis

ab

le

Lo

ad

Lo

ss

Phase L

oss

Mot

or T

herm

D

ec

el Inhib

Au

tR

st

T

rie

s

Shear P

in

Mot

or Ov

er

ld

Mot

or S

tal

l

UnderV

oltage

Po

w

er

L

os

s

Default

x

1

x

x

0

0

0

1

0

0

0

0

1

1

1

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

32

Advertising