Words that control the motion of the stepper motor axis, record
position or monitor move diagnostics are stored in data table files.
These words are grouped into the following three kinds of data
blocks.

Moveset Block

Move Block

Status Block

In addition to move data, the blocks contain special control or status
words. The bits in these words affect how the motion is controlled
or verify that the move commands and the move data were received
and implemented.

Moveset Block

The moveset block is a data table file for storing data and controlling
the motion of one stepper motor axis. It allows move data to be
stored in consecutive data table words to control up to 10 moves of a
positioning profile. Each axis must have at least one moveset block.
A moveset block must contain the following move data (Figure 3.6).

Moveset Control Word

Offset and Preset Words

One or more Moves

Figure 3.6
Moveset Block and Positioning Profile

Moveset Control Word

Offset word

MS Preset Word

LS Preset Word

Move Block # 1

Move Block # 2

Move Block # 3

Move Block # 9

Move Block # 10

64–Word Moveset Block in

Data Table

Move # 1

Interim Moves

Move # 10

10519

Position

Rate

The 64-word moveset block may
contain from 1 to 10 move blocks. If using less than
10 move blocks, fill all unused words with zeros or
a programming error results.