Moveset control word – Rockwell Automation 1771-QA Stepper Positioning Assembly User Manual User Manual

Page 31

Advertising
background image

3–9

Programming and Operation

Publication 1771-UM002A–EN–P – May 2000

Moveset Control Word

A moveset block must contain a moveset control word as the first
word in the block. Each of the bits of the moveset control word
serves a function in the control of a stepper motor axis. Bit functions
of the moveset control word are defined below and summarized in
Figure 3.7.

Figure 3.7
Moveset Control Word

17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00

MCW

Start

Profile Mode Select

Profile Mode Select

Synchronized Axes

Reset

Global/Axis

Stop

Decel/Instantaneous

10520

Override

Moveset

Jog Forward

Jog Reverse

Offset

Not Used (Must be zero)

Axis Address

Axis Address

Axis Addr.

1
2
3

Bit 11

0
1
1

1
0
1

Bit 10

Mode

Continuous

Independent

Single Step

Bit 02

0
1

N/A

0
0
1

Bit 01

2

1

1

2

2

1

Bit 00 Start Command Bit.
When this bit is set, the stepper controller module will start to
execute the first move of a continuous or independent mode
sequence or the next single step move.

Bit 01, 02 Mode Select Bits.
These two bits are used to determine the type of positioning profile.
Bit 01=0, Bit 02=0: Continuous Mode (Figure 3.3)
Bit 01=0, Bit 02=1: Independent Mode (Figure 3.4)
Bit 01=1, Bit 02=1 or 0: Single-Step Mode (Figure 3.2)

Refer to section titled “Positioning Modes” for mode descriptions.

Advertising