3–26

Programming and Operation

Publication 1771-UM002A–EN–P – May 2000

The data address of a block transfer instruction should be the first
available address in the timer/counter accumulated area of the data
table. This address is 030

8

for the Mini-PLC-2/15 controller. For

the PLC-2/30 controller, this address depends on the number of I/O
racks connected to the processor module, i.e. address 020

8

for one

I/O rack, 030

8

for two racks, etc. to 070

8

for six racks and 200

8

for

seven racks. When more than one block transfer module is used, the
data addresses should be consecutive.

Figure 3.16
Block Transfer Instruction Format

BLOCK XFER READ

DATA ADDR
MODULE ADDR

BLOCK LENGTH
FILE

110

110

01

100

030

EN

110

010

07

07

DN

BLOCK XFER WRITE

DATA ADDR
MODULE ADDR

BLOCK LENGTH
FILE

110

110

01

100

030

EN

110

010

06

06

DN

Numbers shown are default values. Numbers in shaded areas must be replacced by uer-entered values. The number of default
address digits initially displayed, 3, 4, or 5 will depend on the size of the data table. Initially displayed default values are governed
by the I/O rack configuration.

Data Address:

Module address:

Block Length:

File:

Enable Bit–( EN )–:

Done Bit –( DN )–:

First possible address in accumulated value area of data table.

Rack module group and slot number.

Number of words to be transferred (00 can be entered for default value or for 64 words.)

Automatically entered from the module address. Set to 1 when rung containing the instruction is true.

Automatically entered from the module address. Remains set to one scan following successful transfer.

10224

Address of first word of file. Storage locations 100

8

above the data address.