The first word in the status block is reserved for future use (Figure
3.14). Each expander module then uses three words, the first of
which is the status word. The remaining two are position words.
The number of status and position words returned to the PC
processor depends on the highest numbered axis in the stepper
positioning assembly, not on the number of axes used. The status
block must contain four words if only axis 1 is in the system, seven
words if axis 2 is the highest numbered axis, and ten words if axis 3
is in the system.