Chapter 3
Communicate with Devices on an Ethernet Network
Specify the path and communication method.
The example path is 1, 6, 2, 10.88.55.186, 1, 2.
This is an example communication method.
This value
Specifies
1
The SoftLogix virtual chassis
6
The sending device (the Ethernet port in the controller’s computer) is in slot 6 of
the virtual chassis
2
Sending the message out the Ethernet communication port
10.88.55.186
The IP address of the 1756-ENBT module
1
The 1756 backplane
2
The slot where the 1756-DHRIO module is in the 1756 chassis
This field
Specifies
Channel = A
Channel A on the 1756-DHRIO module
Source Link = 3
The DH+ address of the 1756-DHRIO module is node 3
Destination Node = 2
The DH+ address of the PLC-5 processor is node 2