Hardware

Monitor

11–3

Publication 6182-UM001D-EN-P

Note:

The temperature is measured on the CPU board, so it
will be higher than the RAC6182 ambient operating
temperature. The RAC6182 operating temperature
rating is specified as ambient temperature outside the
RAC6182 chassis, and internal temperature limits are
set to compensate for expected heat-rise inside the
chassis.

3. Select the Hardware Monitor tab to enable or disable the RAC6182

Hardware Monitor system software. Start the Hardware Monitor
system software by clicking on the box to Enable, and clicking OK.

When enabled, the Hardware Monitor application automatically
starts on power-up, as long as the shortcut remains in the \Storage
Card\Windows\StartUp
folder.

The Clear Fault LED button is used to turn off the front bezel
Diagnostics LED. If any event occurs to turn on this LED, the LED
remains lit even if the operating conditions return to normal.

The RAC6182 last shutdown/boot reason is listed on the bottom of
this window.

4. Select the Event Log tab to view the Hardware Monitor’s Event Log.

All time-stamped diagnostic events, such as an over-temperature,
under-voltage, or low-battery condition, are recorded in the Event
Log. The Event Log is persistent through power cycles. You can
also clear the event log by pressing the Clear Events button.