2. Select the Enable checkbox to turn on the watchdog timer software.

3. Select the desired watchdog timer interval using the slider control

arrows. The interval can be from 0.5 to 4.0 seconds, in 0.1-second
increments.

4. Press Enter or click the OK button to save the settings and exit.

The watchdog timer application automatically starts the next time
you power-up the computer, as long as the shortcut remains in the
\Storage Card\Windows\StartUp folder.

To disable the watchdog timer:

1. To disable the watchdog timer, select Start-Settings-Control Panel.

Select or double-click on the Watchdog icon.

2. On the Watchdog Properties dialog box, clear the Enable check box.

3. Restart the RAC6182 Industrial Computer, and the watchdog timer

application is disabled.